STD Transformer designs and manufactures medium power transformers for transmission and distribution substations, power generation facilities and industrial plants. The catalogue covers ratings from 4 to 50 MVA and voltage levels from 3.3 to 66 kV. Each unit is designed around the network it will serve, with winding arrangements, cooling and voltage regulation specified for the project.
| Parameter | Configuration |
|---|---|
| Transformer type | Oil-immersed medium power transformer |
| Rated power range | 4–50 MVA |
| Voltage level | 3.3–66 kV |
| Frequency | 50 or 60 Hz |
| Phase configuration | Single-phase or three-phase |
| Winding connections | Star or delta, with vector group specified for the project |
| Winding arrangements | Primary and secondary windings, dual or triple secondary windings, or other project-specific arrangements |
| Cooling types | ONAN, ONAF, KNAN, KNAF or OFAF, as applicable |
| Tap changer options | On-load tap changer (OLTC) or off-circuit tap changer |
| Applicable standards | IEC / EN 60076 series, as applicable |
The available combination of power rating, voltage and cooling depends on the selected configuration. The project datasheet identifies the ratings and options agreed for the individual unit.
Medium power transformers are designed around the primary and secondary voltages, load profile and connection requirements of the installation. The electrical specification defines the number of phases, winding connections and vector group. For a new substation, these choices are coordinated with the network design. For a replacement project, the existing transformer’s electrical characteristics and connection layout provide a starting point.
A design can use a single secondary winding or multiple secondary windings. Multiple secondaries can serve circuits with different voltage or loading requirements from one transformer. The design is based on the rated voltage and power of each winding, the required connections and the loads expected to operate at the same time.
The physical arrangement is also part of the specification. Overall dimensions, terminal positions and cooling equipment need to fit the available space and align with the site’s cable or busbar connections. Those details are especially important when a new transformer must fit an existing bay or connect to switchgear already in service.
The cooling system is selected according to the transformer rating, expected loading and site conditions. The catalogue lists ONAN, ONAF, KNAN, KNAF and OFAF configurations. Where a transformer has more than one cooling stage, the project datasheet identifies the rating associated with each specified stage. The substation layout also needs to accommodate the cooling equipment and the space required around it.
Tap changer selection depends on how the installation manages voltage variation. An on-load tap changer adjusts the voltage ratio while the transformer is in service. An off-circuit tap changer allows the ratio to be adjusted when the transformer is de-energised. The tap range, step size and control requirements are defined in the project specification.
STD Transformer tests transformers before dispatch in accordance with applicable IEC 60076 requirements and the agreed project specification. Any additional testing requested by the purchaser is defined during the technical review so that the test scope reflects the transformer configuration and contract requirements.
The technical drawing shows the agreed overall dimensions, terminal positions and accessory locations. The project datasheet records the electrical ratings and selected options. The test report documents the results for the supplied unit, and the maintenance instructions accompany the delivery documentation.
The catalogue lists power ratings from 4 to 50 MVA and voltage levels from 3.3 to 66 kV. The rating and voltage combination is confirmed for the individual project.
Yes. Dual and triple secondary winding arrangements are available. The design depends on the voltage, rating and connection requirements of each winding.
Yes. An OLTC can be specified for applications that require voltage ratio changes while the transformer remains in service. An off-circuit tap changer is also available.
Send the required MVA rating, primary and secondary voltages, frequency, vector group and any specified impedance, losses, cooling or tap changer requirements. For a replacement, include the existing transformer drawing or nameplate data and any limits on dimensions or terminal positions.
For detailed specifications and performance information, please contact us. Our engineering team is ready to support you with your project-specific requirements.