STD Transformer

Cast Resin Transformers | STD Transformer

Oil-Free Power Distribution for Buildings, Industry and Infrastructure

400–5,000 kVA
Up to 45 kV Rated HV Voltage

Cast Resin Transformers

STD Transformer’s cast resin transformers are designed for industrial, commercial and infrastructure projects that specify dry-type power distribution. Resin-encapsulated windings provide solid electrical insulation and mechanical protection. The dry-type design eliminates the need for insulating oil, while the electrical configuration, cooling arrangement and enclosure are selected to suit the load and installation conditions.

ParameterSpecification
Transformer typeCast resin dry-type transformer
Rated power range400–5,000 kVA
Maximum rated HV voltage45 kV
Highest voltage for equipment (Um)Up to 52 kV, where applicable
Insulation systemSolid resin insulation with encapsulated windings
Cooling mediumAir
EnclosureSelected according to the installation environment
Fire performanceSubject to the selected design and material classification

The combination of rated power, winding voltages, equipment voltage class and enclosure is confirmed for each project.

Cast Resin Winding Design

The high-voltage windings are encapsulated in resin, which provides electrical insulation and mechanical protection for the winding assembly. The winding design is specified around the required power rating, primary and secondary voltages and insulation levels. The project specification can also define the vector group, short-circuit impedance and limits for no-load and load losses.

The dry-type construction eliminates oil sampling, oil replacement and the risk of insulating oil leakage. Routine inspection still covers the equipment and its installation, including ventilation openings and any specified temperature monitoring devices. Where the project includes fire performance requirements, the applicable classification is confirmed for the selected resin system and transformer design.

Cooling and Enclosure

Air carries heat away from the windings during operation. In an indoor installation, the transformer room must be able to remove the heat released by the unit and other equipment in the same space. The ventilation review considers the expected load, ambient temperature and location of air inlets and outlets.

The enclosure and cooling arrangement are specified together because the enclosure affects airflow around the transformer. For outdoor substations, a suitable enclosure and installation arrangement are selected for the site conditions. The equipment layout should allow space for cable or busbar connections, inspection and access to the specified accessories.

Where winding temperature monitoring is required, the project specification should identify which alarm or trip signals need to reach the switchgear or site control system. Agreeing those interfaces early helps coordinate accessory selection and wiring with the rest of the installation.

Applications

  • Commercial buildings and high-rise developments. Cast resin transformers can serve building distribution systems where equipment location, access, ventilation and sound limits influence transformer selection.
  • Hospitals and data centres. Dry-type units can be incorporated into distribution systems with defined requirements for load duty, equipment layout and temperature monitoring.
  • Industrial and renewable energy installations. Configurations can be specified around the load profile, voltage levels and connection requirements of manufacturing facilities or renewable energy projects.
  • Airports, railways and transport infrastructure. The design can account for available installation space, cable routing and access for equipment replacement.
  • Indoor and outdoor substations. The enclosure, cooling and terminal arrangement are selected for the substation layout and its environmental conditions.

Specification and Documentation

The project datasheet records the agreed power rating, winding voltages, equipment voltage class and selected configuration. The general arrangement drawing shows the transformer dimensions, termination points and enclosure details. These documents let the project team check the unit against the room layout, switchgear connections and delivery route before installation.

The purchase specification should identify the applicable standards, acceptance criteria and factory test requirements. Where the purchaser requires witnessed tests or additional reporting, these can be defined during technical review alongside the electrical and mechanical requirements.

Frequently Asked Questions

The 45 kV figure is the maximum rated voltage of the high-voltage winding. 52 kV Um is the highest voltage for equipment and identifies the equipment voltage class where applicable. The project datasheet specifies both values for the selected design.

 

 

Yes, with an enclosure and installation arrangement suited to the site conditions. The enclosure and cooling arrangement are reviewed together for the selected unit.

The transformer uses solid insulation and air cooling, so oil sampling and oil replacement are unnecessary. Routine inspection follows the instructions for the supplied unit.

 

The fire performance classification depends on the selected design and materials. State any required classification in the project specification so it can be verified for the offered unit.

 

Share the required kVA rating, primary and secondary voltages, frequency and installation conditions. Where available, include the single-line diagram, layout drawing, enclosure requirements and any specified limits on losses or sound.

 

Get contact

Want to know more?

For detailed specifications and performance information, please contact us. Our engineering team is ready to support you with your project-specific requirements.