STD Transformer designs custom-engineered transformers for projects with specific electrical, mechanical or installation requirements. The transformer can be configured to fit a compact substation, align with existing switchgear or connect to inverter equipment. Customisation can include the tank geometry, high- and low-voltage terminal positions, cooling surfaces and inspection access. These features are defined together so the transformer fits the electrical design and the space available on site.
| Parameter | Configuration |
|---|---|
| Transformer type | Custom-engineered liquid-immersed transformer |
| Tank arrangement | Hermetically sealed or conservator type, as applicable |
| Tank geometry | Configured to suit the equipment layout and installation envelope |
| Cooling surfaces | Corrugated tank walls or radiators, depending on the design |
| Terminal arrangement | Project-specific high- and low-voltage terminal positions, including side-mounted arrangements where applicable |
| Inspection access | Top access via an inspection opening or removable cover, depending on the configuration |
| Rated power, voltage and frequency | Defined for the project and confirmed during technical review |
The shape of the tank and the position of its connections can be adapted to the surrounding equipment. In a compact substation, the transformer may sit beside medium-voltage switchgear, a low-voltage switchboard or an inverter. The tank and terminal layout can be designed around those interfaces so that the connections fit within the available enclosure.
The catalogue describes configurations with side-mounted medium- and low-voltage terminals. A side connection can align the transformer with the cable or busbar approach while leaving the top accessible for inspection. Where the design permits, inspection can be carried out through a dedicated opening or by removing the cover. The required access is agreed during drawing review.
The electrical design begins with the power rating, winding voltages, frequency and network connection requirements. The project specification can also define the vector group, impedance, loss limits and voltage regulation requirements. These values help establish the electrical configuration before the terminal arrangement and tank dimensions are finalised.
The mechanical review covers the installation envelope, the location of adjacent equipment and the space needed to connect and service the transformer. A change in terminal position can affect cable routing, while a change in tank shape can affect the space available for cooling surfaces. These details are reviewed together. For a replacement project, the existing transformer drawing, foundation dimensions and connection positions provide a starting point for the new layout.
A custom tank can be designed around the space available between the transformer and the adjacent switchgear. Terminal positions are coordinated with the switchgear connection points, and the arrangement drawing shows the space needed to route and terminate cables or busbars. The layout also accounts for inspection access once the equipment is installed.
Where a transformer is installed alongside inverter equipment, the tank and connections can be configured around the equipment layout. Reviewing the transformer and inverter drawings together helps align the terminal positions and gives the project team a basis for checking the connection route.
The catalogue describes designs with medium- and low-voltage terminals positioned on the side of the tank. This arrangement can be considered where the connected equipment is located beside the transformer and inspection is intended from above. The agreed drawing identifies the terminal positions and the type of inspection access.
The project datasheet records the agreed electrical ratings and design options. The general arrangement drawing shows the tank dimensions, terminal positions, cooling surfaces and access points. For a custom-engineered unit, the drawing also allows the customer to check the transformer against the equipment layout before manufacturing.
The factory test scope is defined by the applicable standards and project specification. Any requested additional tests, purchaser witness points or reporting requirements are agreed during technical review. The factory test report records the results for the supplied unit.
Depending on the project, the design can include a custom tank, revised terminal positions, a specific cooling arrangement and provisions for inspection access. Electrical characteristics are defined during technical review.
It can be designed around the existing installation. Provide foundation dimensions, terminal positions, available clearances and drawings of adjacent equipment so the layout can be reviewed.
Yes. The catalogue describes custom tank designs for both arrangements. The choice depends on the transformer rating, cooling requirements and installation layout.
Share the required power rating, winding voltages, frequency and single-line diagram. Include the equipment layout, connection drawings, cable entry direction and limits on overall dimensions. For a replacement, add the existing transformer drawing or nameplate data where available.
For detailed specifications and performance information, please contact us. Our engineering team is ready to support you with your project-specific requirements.