Multi-Winding Transformers

Multi-winding transformers use three or more windings to connect multiple circuits within a single unit. The windings can serve different voltage levels or supply separate loads at the same voltage. STD Transformer’s catalogue describes dual and triple secondary arrangements within its medium power range. Each configuration starts with the voltage, power rating and operating duty of every winding.

ParameterConfiguration
Transformer typeMulti-winding power transformer
Catalogue configurationsPrimary with dual or triple secondary windings in the medium power range
Rated power and voltageSpecified for each winding
Winding connections and vector groupDefined by the connection and phase displacement requirements
Short-circuit impedanceSpecified for the relevant winding pairs
Cooling and tap changerSelected to suit the transformer design and operating duty

Winding Arrangements

A common arrangement uses one primary winding and two secondary windings. Each secondary can have its own voltage and power rating. A third secondary may be included where the installation calls for another circuit. The single-line diagram should show what each winding will connect to and how that circuit will operate.

The purpose of each winding is as important as its rating. A secondary that supplies plant equipment throughout the day has a different duty from a winding that serves intermittent auxiliary loads. The specification should describe which circuits operate together, their expected demand and any operating conditions that require a different allocation of power between the windings.

Electrical Design

In a multi-winding transformer, impedance is considered between winding pairs. In a three-winding unit, this includes the primary-to-secondary, primary-to-tertiary and secondary-to-tertiary impedances. These values affect voltage drop and the fault current available to connected equipment. The project team should identify the required impedance values and their reference power bases so that the transformer design can be checked against the network study.

Winding connections and phase displacement are defined by the circuits the transformer will serve. The specification should also identify neutral and earthing requirements, terminal positions and any limits on no-load and load losses. For load-loss guarantees, it is useful to state the winding load combination to which each value applies.

Cooling and Voltage Regulation

Cooling is selected around the expected loading of the complete transformer. The project specification should identify normal operation, peak demand and any operating cases where one winding carries a higher share of the load. Where more than one cooling stage is specified, the datasheet should show the permitted loading for each winding at the corresponding stage.

The voltage regulation specification should identify the winding on which taps are provided and the bus or circuit whose voltage needs to be controlled. A tap change can affect the voltages seen by more than one circuit. The project team should therefore check the allowable voltage variation on each connected circuit when defining the tap range, step size and control requirements.

Applications

  • Industrial power systems. Separate secondary windings can supply different plant sections or equipment groups. The design reflects their respective voltage requirements and how they are loaded in normal operation.
  • Substations. A three-winding arrangement can connect circuits at different voltage levels or provide a tertiary winding for a defined system duty. The network study informs the rating and impedance requirements.
  • Power generation facilities. A multi-winding arrangement can accommodate a main power circuit and an auxiliary circuit where the plant’s electrical design calls for both connections on one transformer.

Testing and Documentation

The purchase specification should identify the applicable standards, factory test scope and acceptance criteria. Any purchaser witness requirements and requested reports can be agreed during technical review so that the test documentation addresses the requirements of the supplied unit.

The project datasheet records the agreed reactive power rating, voltage and configuration. The general arrangement drawing shows the overall dimensions, terminal positions and accessory locations. These documents give the substation team the information it needs to check equipment interfaces and plan installation.

Frequently Asked Questions

Yes. Each winding can be specified for the voltage and power required by its circuit. The design review considers which windings will operate together and the intended loading of each one.

 

That depends on the agreed winding ratings and simultaneous loading conditions. The project datasheet should identify the permitted load combinations.

It is the third winding in a three-winding transformer. Its function depends on the design and can include supplying an auxiliary circuit or meeting a specific network requirement.

 

Provide the single-line diagram, voltage and power rating for each winding, frequency, winding connections, required phase displacement and expected load combinations. Include any specified winding-pair impedances, loss limits and installation constraints.

 