STD Transformer

Conservator Type Transformers | STD Transformer

Oil-Immersed Distribution Transformers with a Separate Expansion Tank

Conservator Type Transformers

STD Transformer’s conservator type transformers are designed for utility, industrial and commercial power distribution. A separate expansion tank, mounted above the main tank, accommodates changes in insulating oil volume as the transformer heats up and cools down. The tank, cooling surfaces, electrical connections and monitoring accessories can be configured to suit the transformer rating and the requirements of the installation.

ParameterConfiguration
Transformer typeOil-immersed distribution transformer
Oil expansion systemSeparate conservator mounted above the main tank
Breathing systemSilica gel breather for free-breathing configurations
Tank and cooling surfacesCorrugated tank walls or radiators, depending on the design
Tap changerFive-position off-circuit tap changer
High-voltage bushingsDIN 42531 or EN 50180, as applicable
Low-voltage bushingsDIN 42530 or EN 50386, as applicable
Monitoring and protectionThermometer pocket, contact thermometer and Buchholz relay, as applicable
Applicable transformer standardsIEC 60076 series, as applicable to the project

Conservator Tank Design

The conservator is an expansion vessel connected to the transformer’s main tank. As the insulating oil warms during operation, it expands and the oil level in the conservator rises. When the transformer cools, the oil contracts and the level falls. This arrangement gives the oil room to change volume as the load and ambient temperature vary.

In a free-breathing configuration, air entering the conservator passes through a silica gel breather. The desiccant absorbs moisture from the incoming air, helping limit the amount of moisture that reaches the oil. A flexible separator can be specified for suitable designs to keep the oil apart from the air in the conservator. The arrangement is selected as part of the project specification.

Cooling and Electrical Configuration

Depending on the transformer design, heat is dissipated through corrugated tank walls or separate radiators. The choice affects the unit’s overall dimensions and the space needed around it. When reviewing a substation layout, allow for the conservator above the main tank as well as the space occupied by cooling surfaces, bushings and accessories.

The electrical configuration is specified around the required power rating, primary and secondary voltages, and the connection arrangement at the site. The standard five-position off-circuit tap changer allows the voltage ratio to be matched to the supply conditions. High- and low-voltage bushing arrangements should be reviewed with the cable routing or switchgear layout before the transformer drawing is approved.

Protection and Accessories

A Buchholz relay can be fitted in the pipe between the main tank and the conservator. It can detect gas accumulation and sudden oil movement associated with certain internal faults. The relay configuration and its alarm or trip signals are specified according to the transformer rating and the requirements of the site protection system.

The catalogue configuration includes a thermometer pocket. A contact thermometer can be specified where temperature signalling is required. Lifting lugs, earthing terminals, a rating plate, an oil filling plug and a drain valve support installation and servicing. Bidirectional rollers are also listed in the catalogue. Their suitability depends on how the transformer is positioned on site.

Applications

Conservator type transformers are used in utility substations, industrial facilities and commercial developments where the distribution system calls for an oil-immersed unit with a separate expansion vessel. A utility project may specify a particular bushing arrangement and remote alarm contacts. An industrial project may put more emphasis on load variation, installation clearances and integration with existing switchgear.

For replacement projects, the existing transformer drawing can help identify constraints on tank dimensions, wheel spacing and terminal positions. The overall height deserves particular attention because it includes the conservator and its associated fittings.

Testing and Documentation

STD Transformer tests transformers before dispatch in accordance with the applicable IEC 60076 requirements and the agreed project specification. The technical drawing identifies the transformer dimensions, terminal positions and accessory locations. The project datasheet and test report provide the agreed ratings and relevant test results. Maintenance instructions accompany the supplied unit.

Frequently Asked Questions

A conservator type transformer accommodates oil expansion in a separate vessel connected to the main tank. A hermetically sealed transformer accommodates expansion within a sealed system, typically through flexible corrugated tank walls or a nitrogen cushion.

 

It absorbs moisture from the air drawn into a free-breathing conservator as the oil cools and contracts. Inspection and servicing should follow the instructions supplied for the transformer.

Yes. The catalogue lists it as available on request or recommended from 800 kVA. Confirm the relay and required alarm or trip contacts when specifying the unit.

 

Send the required kVA rating, primary and secondary voltages, frequency, installation conditions and applicable standards. For a replacement unit, include the existing drawing, available clearances and connection details.

 

Get contact

Want to know more?

For detailed specifications and performance information, please contact us. Our engineering team is ready to support you with your project-specific requirements.